Illumination and radiation

DELTA OHM

 

 

Light sensors

MODEL SPECIFICATIONS
DELTA OHM HD 2021 T Lighting transmitter. Spectrum Curve V(?). Si photo-diode sensor  pdf
HD 2021 T1 Lighting transmitter. Spectrum 450 ...950 nm. Si photo-diode sensor 
HD 2021 T2 Lighting transmitter. Spectrum UVA. GaP photo-diode sensor 
HD 2021 T3 Lighting transmitter. Spectrum UVB. SiC photo-diode sensor 
HD 2021 T4 Lighting transmitter. Spectrum UVC. SiC photo-diode sensor 
HD 2021 T6 Lighting transmitter. Spectrum Curve V(?).  Si photo-diode sensor

Photometric sensors

MODEL SPECIFICATIONS
DELTA OHM LP PHOT 01 Photometric sensor for measuring luminescence pdf
LP RAD 01 Radiometric sensor for measuring irradiance
LP PAR 01 Radiometric  sensor for measuring  PAR
LP UVA 01 Radiometric sensor for measuring  UVA
LP UVB 01 Radiometric sensor for measuring  UVB
LP UVC 01 Radiometric sensor for measuring  UVC
DELTA OHM LP PHOT 02 Photometric sensor for measuring luminescence in lux
LP PHOT 02 AC Photometric sensor for measuring luminescence in lux . Output signal 4..20 mA
LP PHOT 02 AV Photometric sensor for measuring luminescence in lux . Output signal 0..1 V, 0..5 V, 0..10V
LP UVA 02 Radiometric sensor for measuring  UVA
LP UVA 02 AC Radiometric sensor for measuring  UVA Output signal 4..20 mA
LP UVA 02 AV Radiometric  sensor for measuring  UVA Output signal 0..1 V, 0..5 V, 0..10V
LP UVB 02 Radiometric sensor for measuring  UVB
ACCESSORIES
MODEL SPECIFICATIONS
DELTA OHM LP BL Leveling Base for Probes/Sensors pdf
LP S1 Bracket to attach the sensors
LP S2 Equipment to fix rod & level LP to PYRA 03 base
LP SP1 Plastic  UV protection screen
LP SG Cartridge for silicon crystals including OR
LP G Pack of 5 silicon crystals
DELTA OHM HD 978 TR3 Configurable signal converter. Input -10 to 60 mV. Output 4...20 mA pdf
HD 978 TR4 Configurable signal converter. Input -10 a 60 mV. Output 0...10V
HD 778 TCAL Signal Simulator. Power Voltage range -60/+60 mV.

Luminescence

Albedo-meter & Pyrometers

PYROMETERS

MODELS SPECIFICATIONS
DELTA OHM LP PYRA 02 Class I Pyrometer, standard  ISO 9060. pdf
LP PYRA 02 AC Class I Pyrometer, standard ISO 9060. Output 4...20 mA
LP PYRA 02 AV Class I Pyrometer, standard  ISO 9060. Output 0...1V DC 0...5 V DC 0...10 V DC
DELTA OHM LP PYRA 03 Class II Pyrometer, standard ISO 9060.
LP PYRA 03 AC Class II Pyrometer standard  ISO 9060. Output 4...20 mA
LP PYRA 03 AV Class II Pyrometer, standard ISO 9060. Output 0...1V DC 0...5 V DC 0...10 V DC
DELTA OHM LP PYRA 12 Class I Pyrometer  ISO 9060 standard. With shadow ring.
LP PYRA 12 AC Class I Pyrometer ISO 9060 standard. With shadow ring. Output 4...20 mA
LP PYRA 12 AV Class I Pyrometer  ISO 9060 standard. With shadow ring..Output 0...1V DC 0...5 V DC 0...10 V DC

ALBEDO-METROS

MODEL SPECIFICATIONS
DELTA OHM LP PYRA 05 Albedo-meter composed of 2 class I Pyrometers ISO 9060 standards. pdf
LP PYRA06 Albedo-meter composed of 2 class II Pyrometers ISO 9060 standards.

NET IRRADIANCE METER (RADIOMETER)

MODEL

SPECIFICATIONS
lpnet07 LP NET 07 Net radiometer is designed to measure the Net radiation passing through a surface, across the spectral range between the near ultraviolet and the far infra-red. The Net radiation is defined as the difference between the radiation that strikes the top surface, and the radiation that strikes the bottom surface of the net radiometer. pdf

ACCESSORIES

MODEL SPECIFICATIONS
DELTA OHM
lpsp1
LP S1 For fixing pyrometers pdf
LP S2 Rod and level to fix the LP to the PYRA 03  base
LP SP1 Protective screen for the LP PYRA 05
LP SP2 Protective screen for the LP PYRA 03
LP SP3 Protective screen for the LP PYRA 05
LP SG Cartridge of silicone crystals including OR
LP G Pack of 5 silicone crystals
CP AA 1.5 Cable of 4 poles L= 5 m for LP PYRA 02 LP PYRA 03 LP PYRA 12 LPPhot 02, LP UVA 02. Resistant to UV radiation.
CP AA 1.10 Cable of 4 poles L= 10 m para LP PYRA 02 LP PYRA 03 LP PYRA 12 LPPhot 02, LP UVA 02. Resistant to UV radiation.
CP AA 2.5 Cable of 7 poles L= 5 m for LP PYRA 05 LP PYRA 06 LP UVB 02. Resistant to UV radiation.
CP AA 2.10 Cable of 7 poles L= 10 m for LP PYRA 05 LP PYRA 06 LP UVB 02. Resistant to UV radiation.
DELTA OHM HD 978 TR3 Configurable signal converter. Input -10 a 60 mV. Output 4...20mA pdf
HD 978 TR4 Configurable signal converter. Input -10 a 60 mV. Output 0...10V
HD 778 TCAL Signal simulator. Power voltage range -60/+60mV.
 a DC ording to Class I